PRODUCT TESTING INFORMATION
UNDERWRITERS LABORATORY INC.
U/L's online certification directory provides listing information on The Philipp Manufacturing Company products.
GVTV.R3207 - Fire Door and Fire Window Frames
GSYN.R3780 - Swinging-Type Fire Doors
GSZN.R3780 - Swinging-Type Fire Doors, Positive Pressure
OPBW.R3780 - Air Leakage Test of Doors Assemblies, ANSI/UL 1784
Additional information regarding specialized testing assemblies in which Philipp's has participated are listed, including specific construction, size, and hardware.
INTERTEK TESTING SERVICES, NA, INC.
ANSI A250.4 - Testing Procedure and Acceptable Criteria for Physical Endurance for Steel Doors, Frames, Frame Anchors, and Hardware Reinforcing. Testing criteria, maximum 1,00,000 cycles. Testing conducted on a nominal 3'-0" x 7'-0" flush door and welded frame, Typical product passed 1,000,000 cycles. 16 Ga. Steel Stiffened Door & 14 Ga. Frame - passed 4,000,000 cycles, test was stopped.
Latest testing conducted in 2021: Windstorm Resistant Testing
Product: Thermally broken 14 Ga. A60 Galvannealed Frame & 16 Ga. Galvannealed Door with internal core assembly consisting of rigid polyurethane board sandwiched between 'Z' shaped steel channels welded to a internal flat steel sheet. Internal core assebly laminated to face sheets.
Testing Criteria:
ASTM E330 - Standard Test Method for Structural Performance of Exterior Windows, Doors, Skylights, and Curtain Wall by Uniform Static Air Pressure.
ASTM E1886 - Standard Test Method for Performance of Exterior Windows, Curtain Walls, Doors, and Impact Protective Systems by Missiles and exposed to Cyclic Pressure Differentials.
ASTM F1996 - Standard Specifications for Performance of Exterior Windows, Curtain Walls, Doors, and Impact Protective Systems by Windborne Debris in Hurricanes.
Met Performance requirements for Missile Level D, Wind Zone 4
ASTM C1363-11 - Standard Test Method for the Thermal Performance of Building Materials and Envelope Assemblies by means of a Hot Box Apparatus.
Thermal Transmittance (U) : 0.57 btu/hr-sq. ft-F.
ANSI A250.4 (2011) - Test Procedure and Acceptance Criteria for Physical Endurance for Steel Doors, Frames, and Frame Anchors.
Compliant to all applicable sections for level A (1,000,000 cycles)
ARCHITECTURAL TESTING, INC.
ASTM E90 - Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements.
18 Ga. Honeycomb Core Door & 16 Ga. Welded Frame - STC 35, OITC 30
16 Ga. Honeycomb Core Door & 16 Ga. Welded Frame - STC 36, OITC 32